Phase I of this study was a screening experiment to determine which plating and treatment parameters contribute to microvoid formation. Phase I indicated correlations with current density, solder alloy, bath age, wetting agent, brightener content, and copper layer thickness. There were also strong interactions of the above, all involving the wetting agent.